Uncertainty Distribution of Air Infiltration Rates of Thai Detached Homes for Energy Model
Main Article Content
Abstract
Air infiltration through building envelope is considered as a path of outdoor air ventilation in modern Thai detached homes where there is no outdoor air intake in an air condition unit. At present, there are limited studies of air infiltration rate through building envelope for Thai homes and such few studies are insufficient for establishing a database of air infiltration rate for evaluating home energy performance. This present study used a multi-zone airflow model to calculate air infiltration rates in 134 homes from 137 housing development projects located in suburban areas near Bangkok. The calculated air exchange rate (air infiltration) ranged from 0.33-0.58 h-1 with an average value of 0.43 h-1 (s.d. = 0.04). Compared to the ventilation standards, the calculated air exchange rates were approximately 1.7 times greater than the required ventilation rates defined by the ASHRAE Standard 62.2 (2007) and 93% of those achieved the required ventilation rate prescribed in the Thai Building Control Act B.E. 2522 (2015). Consequently, it has a potential to reduce air infiltration rate for modern Thai detached home to save home energy consumption. The default air infiltration rate typically used in energy models provided a maximum input error ranged from 7-65% when compared to the calculated air infiltration rates.
Downloads
Article Details
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
All material is licensed under the terms of the Creative Commons Attribution 4.0 International (CC-BY-NC-ND 4.0) License, unless otherwise stated. As such, authors are free to share, copy, and redistribute the material in any medium or format. The authors must give appropriate credit, provide a link to the license, and indicate if changes were made. The authors may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use. The authors may not use the material for commercial purposes. If the authors remix, transform, or build upon the material, they may not distribute the modified material, unless permission is obtained from JARS. Final, accepted versions of the paper may be posted on third party repositories, provided appropriate acknowledgement to the original source is clearly noted.
References
Alpan Clear Performance Products. (n.d.). Why air infiltration matters for energy efficient windows. Retrieved from http://thinkalpen.com/resources/why-air-infiltration-matters-for-energy-efficient-windows/
Architectural Energy Corporation. (2004). VisualDOE 4.0 user manual. San Francisco, CA, USA.: Author. Retrieved from http://staging.archenergy.com/assets/files/VisualDOE_Manual.pdf
ASHRAE. (1997). Chapter 25 handbook of fundamentals. Atlanta: Author.
ASHRAE. (2009). Handbook of fundamentals. Atlanta: Author.
ASHRAE. (2007). Ventilation and acceptable indoor air quality for low-rise residential buildings, ASHRAE Standard 62.2-2007. Atlanta: Author.
Building Control Act B.E. 2522. (1979). Article index: Thai law texts. Retrieved from http://www.samuiforsale.com/law-texts/thailand-building-control-act-in-thai.html
Chan, W. R., Nazaroff, W. W., Price, P. N., Sohn, M. D. & Gadgil, A. J. (2005). Analyzing a database of residential air leakage in the United States. Atmospheric Environment, 39(19), 3445–3455.
Chan, W. R., Joh, J. & Sherman, M. H. (2013). Analysis of air leakage measurements of US houses. Energy and Buildings, 66, 616–625.
Chartered Institution of Building Services Engineers [CIBSE]. (2006). Environmental design: CIBSE guide A. London: Author.
DesignBuilder. (2009). DesignBuilder simulation + CFD traning guide. Gloucs. UK.: Author. Retrieved from http://www.designbuilder.co.uk/downloadsv1/doc/DesignBuilder-Simulation-Training-Manual.pdf
Emmerich, S. J. & Persily, A. K. (1996). Multi-zone modeling of three residential indoor air quality control options. Gaithersburg, MD.: National Technical Information Service [NISTIR].
Goswami, D. Y. & Kreith, F. (2015). Chapter 31: Analysis methods for building energy auditing. In M. Krarti. Energy Efficiency and Renewable Energy Handbook (2nd ed.) (pp.869-888). Boca Raton, FL: CRC Press.
Grot, R. A. & Clark, R. E. (1979). Air leakage characteristics and weatherization techniques for low-income housing. Proceedings of ASHRAE/DOE Conference, Thermal performance of the exterior envelopes of buildings. Kissimmee, FL.
Hirsch, J. J. (2010). eQUEST introductory tutorial, version 3.64. Retrieved from http://doe2.com/download/equest/eQ-v3-64_Introductory-Tutorial.pdf
Jareemit, D. & Shu, S. (2014). An investigation of the impact of building entrance vestible on indoor humidity using a calibrated multi-zone model for a small supermarket in hot and humid climate. International Journal of Building, Urban, Interior and Landscape Technology, 3, 23-32.
Jareemit, D. & Inprom, N. (2015). ตัวแปรสำคัญสำหรับการจำลองพลังงานในอาคาร [Review Article: Significant parameters in building energy simulation]. Journal of Architecture/Planning Research and Studies, 12(1), 1-14.
Jokisalo, J., Kurnitski, J., Korpi, M., Kalamees, T. & Vinha, J. (2009). Building leakage, infiltration, and energy performance analyses for Finnish detached houses. Building and Environment, 44(2), 377–387.
Marsh, A. J. (2006). Thermal modelling: The Ecotect Way. Enviromental Design Journal, 2. Retrieved from http://naturalfrequency.com/articles/thermalelements.
Namtaveesuk, S. (2000). แนวทางการสร้างแบบประเมินค่าการรั่วซึมของอากาศผ่านทางประตู-หน้าต่าง และผนังของอาคารพักอาศัยที่มีการปรับอากาศ [An approach to formulate energy conservation index for through doorswindows and walls of air-condition buildings]. Master of Architecture Thesis, Chulalongkorn University: Bangkok (Thailand). Retrieved from http://www.thaithesis.org//detail.php?id=1082546000718&language=thai
National Renewable Energy Laboratory. (2008). National solar radiation data base: 1991- 2005 Update: Typical meteorological year 3. Retrieved from http://rredc.nrel.gov/solar/old_data/nsrdb/1991-2005/tmy3/
Pandian, M., Behar, J., Ott, W., Wallace, L., Wilson, A., Colome, S. & Koontz, M. (1998) Correcting errors in the nationwide database of residential air exchange rates. Journal of Exposure Analysis and Environmental Epidemiology, 8, 577–586.
Persily, A. K. (1998). A modeling study of ventilation, IAQ and energy impacts of residential mechanical ventilation, NISTIR 6162. National Institute of Standards and Technology, Gaithersburg, MD.
Persily, A. K. (2000). A modeling study of ventilation in manufactured houses, NISTIR 6455. National Institute of Standards and Technology, Gaithersburg, MD.
Persily, A., Musser, A. & Emmerich, S. J. (2010). Modeled infiltration rate distributions for U.S. housing. Indoor Air, 20(6), 473–485.
Sherman, M. (2009). Infiltration in ASHRAE’s Residential Ventilation Standards. ASHRAE Transactions, 115, 887–896.
Sherman, M. & Dickeroff, D. (1998). Airtightness of U.S. Dwellings. ASHRAE Trans., 104, 1359–1367.
Srisuwan, P. & Varodompun, J. (2013). Field CO2 monitoring of rooms with different air-tightness classes and ventilation systems. International Journal of Building, Urban, Interior and Landscape Technology, 2, 5-20.
Sutthi, K. (2011). ผลกระทบของการรั่วซึมของอากาศต่อผลการใช้พลังงานในระบบปรับอากาศของเรือนไทยและบ้านร่วมสมัย [Impacts of air infiltration on cooling energy use of Thai house]. Master of Architecture Thesis, Chulalongkorn University: Bangkok (Thailand). Retrieved from http://cuir.car.chula.ac.th/handle/123456789/30019
Walton, G. N. & Dols, W. S. (2005). CONTAMW 2.4 User Guide and Program Documentation, NISTIR 7251. National Institute of Standards and Technology, Gaithersburg, MD.
Yamamoto, N., Shendell, D. G., Winer, A. M. & Zhang, J. (2010). Residential air exchange rates in three major US metropolitan areas: results from the Relationship Amoung Indoor, Outdoor, and Personal Air Study 1999-2001. Indoor Air, 20(1), 85–90.